Span endpoints screen, Span endpoints screen -10 – Verilink WANsuite 6450 (34-00326) Product Manual User Manual
Page 38

3-10
W A N s u i t e 6 4 5 0
15-minute collection interval reaches/exceeds this value, a trap is generated.
One trap will be sent per interval per endpoint. A value of 0 (zero) disables
the trap.
SES
Sets the threshold for the number of Severely Errored Seconds within any
given 15-minute performance data collection interval. If the value of SES in a
particular 15-minute collection interval reaches/exceeds this value, a trap is
generated. One trap will be sent per interval per endpoint. A value of 0 (zero)
disables the trap.
CRC
Sets the threshold for the number of Cyclic Redundancy Check anomalies
within any given 15-minute performance data collection interval. If the value
of CRC anomalies in a particular 15-minute collection interval reaches/
exceeds this value, a trap is generated. One trap will be sent per interval per
endpoint. A value of 0 (zero) disables the trap.
LOSWS
Sets the threshold for the number of Loss of Sync Word Seconds within any
given 15-minute performance data collection interval. If the value of LOSW
in a particular 15-minute collection interval reaches/exceeds this value, a trap
is generated. One trap will be sent per interval per endpoint. A value of 0
(zero) disables the trap.
UAS
Sets the threshold for the number of Unavailable Seconds within any given
15-minute performance data collection interval. If the value of UAS in a
particular 15-minute collection interval reaches/exceeds this value, a trap is
generated. One trap will be sent per interval per endpoint. A value of 0 (zero)
disables the trap.
NOTICE:
Any changes to the above-listed parameters must be followed by a
“Submit” for the changes to take effect.
Span Endpoints Screen
Clicking on the “Span Endpoints” button on the Network screen will display
the screen shown in Figure 3.9.
Figure 3.9
Span Endpoint Table Screen
This screen displays each endpoint of the span. If the SHDSL link is not up,
only the local side of the span is displayed. The EOC channel is used to
access the remote end unit
Clicking on the highlighted (linking) Type identifier in the table on the Span
Endpoints screen will display the Span Endpoints Details screen (Figure 3.10).
This table supports retrieval of unit inventory information available via the