beautypg.com

Originate ping, Originate ping -75 – Verilink WANsuite 6450 (34-00326) Product Manual User Manual

Page 183

background image

V T 1 0 0 I n t e r f a c e

4-75

System Up Time

Displays the amount of time that the unit has been operational since it was
turned on or last reset.

The Top Talkers table reports in descending order the IP Addresses that have
generated the most traffic during the requested report’s duration. For each IP
Address listed, the report displays the number of Rx frames, Rx octets, Tx
frames, and Tx octets that have been passed across it. In addition, the
Timestamp field indicates the time at which a packet was examined for the
specified IP Address.

Originate Ping

The WANsuite 6450 Originate Ping (Figure 4.68) function helps telephone
companies determine if a network is properly configured and also helps them
maintain SLAs.

Figure 4.68

Originate Ping Screen

The parameters on the left side of the screen offer you the following choices:
Start Ping, Stop Ping, or Reset the Status (clears all counts activity). Other
parameters include the following:

Dest IP Address

Destination IP Address of sent Ping request messages.

Number to Send

Number of Ping request messages to send.

Values: 1

10,000

Default: 5

Ping Size

Number of bytes in a Ping request message.

Values: 4

4096 bytes

Default: 64 bytes

Ping Reply Timeout

Number of seconds to wait for a reply to a Ping request message.

Values: 1

60 s

Default: 1 s