Lifter interface cable, 2 – installation lifter interface cable – Hypertherm THC ArcGlide User Manual
Page 98

98
ArcGlide THC Instruction Manual 806450
2 – Installation
Lifter interface cable
Part number
Length
Part number
Length
223219
3.0 m (10 feet)
223115
23.0 m (75 feet)
223220
6.0 m (20 feet)
223116
30.5 m (100 feet)
223120
7.5 m (25 feet)
223117
45.5 m (150 feet)
223221
10.5 m (35 feet)
223118
61.0 m (200 feet)
223007
15.0 m (50 feet)
Pin No.*
Color and size
Signal name
1
Red 1.31 mm
2
(16 AWG)
Motor +
2
Black 1.31 mm
2
(16 AWG)
Motor -
3
Black 0.82 mm
2
(18 AWG)
Brake -
4
Brown 0.33 mm
2
(22 AWG)
Common -
5
Brown 0.82 mm
2
(18 AWG)
Power +24 VDC
6
Gray 0.33 mm
2
(22 AWG)
Ohmic contact sense common
7
White 0.33 mm
2
(22 AWG)
Ohmic contact sense
8
Violet 0.33 mm
2
(22 AWG)
Ohmic contact sense bias +12 VDC
9
Black 0.33 mm
2
(22 AWG)
Encoder common
10
Red 0.33 mm
2
(22 AWG)
Lifter station active
11
White/Blue 0.33 mm
2
(22 AWG)
Encoder input B -
12
Blue 0.33 mm
2
(22 AWG)
Encoder input B +
13
White/Yellow 0.33 mm
2
(22 AWG)
Encoder input A -
* Pin numbers are the same on both ends of the cable.
Red band
Diameter = 20.07 mm (0.79 inch)
Bend radius = 150.00 mm (6.00 inch)
Connect one end to the port on the control
module with the red circle. Connect the other
end to the top of the lifter.