ArcGlide THC Instruction Manual 806450
2 – Installation
6 – Discrete plasma interface board with connection to an HPR or HPRXD plasma system
1
2
7
8
6
5
PULL UP
24V *
J2-2
FIELD COMMON
J2-1
J2-3
FIELD COMMON
J2-4
J2-6
FIELD COMMON
J2-5
J2-7
FIELD COMMON
J2-8
J2-10
FIELD COMMON
J2-9
J2-11
J2-12
J2-13
J2-14
J2-16
J2-15
J3-2
J3-1
RELAY
CORNER
PIERCE
RELAY
J3-3
J3-4
J3-8
J3-7
RELAY
PLASMA START
HOLD
RELAY
J3-5
J3-6
SPARE
RELAY
J3-9
J3-10
J3-12
J3-11
RELAY
REMOTE ON
J2-14
FIELD COMMON
J2-13
J2-15
+24V THC
J2-16
24V
3
4
2
1
9
10
11
12
13
14
15
16
24V *
PULL UP
PULL UP
24V *
PULL UP
24V *
4
3
6
5
8
7
10
9
12
14
11
13
FUTURE USE
FOR I/O USE IF NEEDED
500MA MAX
ARC XFER
D3
D4
THC ON
D2
PLASMA STRT
PLASMA ON
D1
15
16
5 Rampdown error
2 Common
3 Error
4 Common
6 Common
7 Not ready
8 Common
9 Spare in
14 Common
16 Not connected
12 Remote ON B
11 Remote ON A
14 Common
13 Common
16 Field +24 V out
15 Field +24 V out
1 Motion**
6 Hold B
5 Hold A
8 Plasma Start**
7 Plasma Start A**
10 Spare out B
9 Spare out A
DB37 to DB37 interface cable
(123760)
2 Corner B
1 Corner A
4 Pierce B
3 Pierce A
To terminal block 2,
pins 1 and 3
Electrode -
Work +
J2 Inputs
J3 Outputs
J2 Inputs
J3 Outputs
** Motion and Start are the minimum connections. Use other signals if they are
supported by the plasma system.
10 Common
11 Common
12 Common
13 Common
15 Not connected
Discrete plasma interface board (141094)
Arc voltage sense wires to
plasma system, use ~0.9 mm
2
(18 AWG) twisted pair wire,
rated 600 V or greater.
To plasma system Electrode-
To plasma system Work+
* 24 V pull-up resistors on inputs are active only if they are set to dry (D) on the ArcGlide control module