Hypernet and hmi interface cable – Hypertherm THC ArcGlide User Manual
Page 100
![background image](https://www.manualsdir.com/files/789505/content/doc100.png)
100
ArcGlide THC Instruction Manual 806450
2 – Installation
Hypernet and HMI interface cable
In a Hypernet or mixed configuration where there is more than one Hypernet connection, use these cables to connect the
components of the system to the Ethernet switch.
If you use Ethernet cable from another supplier, make sure that the cable is a standard, shielded RJ-45 Cat5e or Cat6
cable.
Part number
Length
Part number
Length
223212
3.0 m (10 feet)
223099
23.0 m (75 feet)
223222
6.0 m (20 feet)
223100
30.5 m (100 feet)
223119
7.5 m (25 feet)
223101
45.5 m (150 feet)
223223
10.5 m (35 feet)
223102
61.0 m (200 feet)
223008
15.0 m (50 feet)
Pin No.*
Signal name
1
Tx + (transmit data +)
2
Tx - (transmit data -)
3
Rx + (receive data +)
4
Not connected
5
Not connected
6
Rx - (receive data -)
7
Not connected
8
Not connected
* Pin numbers are the same on both ends of the cable.
Diameter = 6.35 mm (0.25 inch)
Bend radius = 152.40 mm (6.00 inch)
Connect one end to the control module or Ethernet switch.
Connect the other end to the ArcGlide HMI.