Hypertherm THC ArcGlide User Manual
Page 107

ArcGlide THC Instruction Manual 806450
107
2 – Installation
All ArcGlide CNC inputs can be configured for dry contact closures or 12 V – 24 V sourced inputs.
Pin No.*
Color
Signal name
Dry contact or sourced circuit
13
Orange
IHS Complete output A
14
Black
IHS Complete output B
15
White
Retract Complete output A
16
Red
Retract Complete output B
17
Green
Machine Motion output A
18
Red
Machine Motion output B
19
Blue
THC Error output A
20
Red
THC Error output B
21
Yellow
Torch Breakaway output A
22
Red
Torch Breakaway output B
23
Brown
CNC Spare output A
24
Red
CNC Spare output B
25
Orange
Motion Interlock input +
**
26
Red
Motion Interlock input -
**
27
White
Interlock output A
28
Green
Interlock output B
29
Blue
Common
30
Green
Common
31
Yellow
Common
32
Green
Common
33
Brown
+24 VDC output
34
Green
+24 VDC output
35
Orange
+24 VDC output
36
Not connected
37
Not connected
*
Pin numbers are the same on both ends of the cable.
**
The circuit is closed if a jumper is used.
normally open
A
B
normally open
A
B
normally open
A
B
normally open
A
B
normally open
A
B
normally open
A
B
+24 V
A
B
+24 V
+24 V
+24 V