ArcGlide THC Instruction Manual 806450

2 – Installation

Connect Hypernet cables

A system configuration in which there is more than one Hypernet connection requires an industrial-grade Ethernet switch.
See

Ethernet switch on page 46 for more information.

In this type of configuration, Hypernet connections are made from the ArcGlide control module directly to the Ethernet
switch and from there to the CNC or plasma system. See

Figure 11 on page 59 for an example.

Each unit assigned to a station must have the same Hypernet address. This common address between units allows
the Ethernet switch to direct communications to the appropriate station. See

Figure 25 for an example.

Figure 25

See the following pages for details:

See

Assign an ArcGlide THC to a station on page 125 for information about linking unit addresses to a station in

Phoenix software on a Hypertherm CNC.

See the following sections for the location of the unit address switches:

HMI processor board (228581) on page 211

THC processor board (228578) on page 220

Hypernet plasma interface board (141162) on page 228

Hypernet connections and Ethernet connection to a LAN cannot be made through the same switch. If your cutting
machine is connected to a LAN over Ethernet, you must use a separate Ethernet switch for these connections.

Station 1

Lifter

HPR plasma system

HMI

Hypernet address: 1

ArcGlide control module

Hypernet address: 1

Hypernet plasma interface

board

Hypernet address: 1

HyPath CNC

Ethernet switch

Station 2

HMI

Hypernet address: 2

ArcGlide control module

Hypernet address: 2

HPR plasma system

Hypernet plasma interface

board

Hypernet address: 2

Lifter

Key:

Hypernet connection

Discrete connection