System description for a serial configuration, Arcglide thc replacement for command thc – Hypertherm THC ArcGlide User Manual
Page 274
![background image](https://www.manualsdir.com/files/789505/content/doc274.png)
274
ArcGlide THC Instruction Manual 806450
B – ArcGlide THC Serial Communication Installation
System description for a serial configuration
ArcGlide THC replacement for Command THC
Figure 49 shows an ArcGlide THC that has replaced a Command THC. In this configuration, the ArcGlide operates and
communicates with the rest of the system using the serial protocol, as if it were a Command THC, as described in
ArcGlide THC Serial Communication Installation on page 269. For more information, refer to the illustration in
Connecting cables for a Command THC replacement on page 276.
Figure 49
Customer-supplied operator
console (optional):
- Station on/off/program switch
- Station active lamp
- Lifter UP/DOWN switch
CNC
ArcGlide lifter
HMI (optional)
ArcGlide control module
Existing CNC I/O cable, for
serial and discrete signals
Serial signals
Existing plasma I/O cable,
for arc voltage and discrete
signals
Discrete signals only
Plasma system
Key:
Hypernet connection
– – – – – – –
Discrete connection
———————–
Serial connection
- - - - - - - - - - -