Hypertherm THC ArcGlide User Manual
Page 73
ArcGlide THC Instruction Manual 806450
73
2 – Installation
11 – ArcGlide with discrete connection to a Picopath interface CNC
A
B
D S
D S
CNC PLASMA
17
18
INPUT 12
OUTPUT 10
OUTPUT 11
OUTPUT 12
5
7
1
26
25
INTERLOCK
12
32
31
30
MOTION
CYCLE START
AVC DISABLE
IHS SYNC
24V COMMON
COMMON
31
24V
PULL UP
24V
PULL UP
24V
PULL UP
CUT/MARK
SENSE
RELAY
BREAKAWAY
BREAKAWAY
37
11
INPUT 11
22
21
COMMON
JUMPER
JUMPER
COMMON
29
30
TORCH
INPUT
24V
+24V
+24V
Picopath CNC end A
CNC I/O cable
Picopath interface CNC
I/O
Axes 1, 2
Axes 3, 4
ArcGlide control module
ArcGlide control module end B
Set dry contacts by sliding
the switch to D.
Picopath connector kit (228490)
End A of the Hypertherm ArcGlide CNC I/O cable is terminated during installation and will work only if the I/O setup in Phoenix software corresponds to the setup
described in this half of this table.
End B of the Hypertherm ArcGlide CNC I/O cable is terminated at the
factory as described in this half of the table.
Pin No.
Function*
Phoenix mapping name
Wire color*
Pin No.
Signal
32
Output 12
Cut Control
Red
1
Cycle start input +
31
Output 11
Hold Ignition
Blue
7
IHS sync input +
30
Output 10
Torch Height Disable
Green
5
AVC disable input +
12
Input 12**
Cut/Mark Sense
Green
17
Machine motion output A
Jumper blue and red, pins 18 and 29.
Red
18
Machine motion output B
Blue
29
Common
11
Input 11**
Torch Collision
Yellow
21
Torch breakaway output A
Jumper red and green, pins 22 and 30.
Red
22
Torch breakaway output B
Green
30
Common
External switch
Satisfy with switch or jumper.
Orange
25
Interlock input + **
Red
26
Interlock input - **
37
24 V common
Yellow
31
Common
Backshell
Chassis ground
Drain wire
Ring terminal Chassis ground
* This example uses CNC outputs 10, 11, 12, and inputs 11 and 12. Assign the I/O points in the Phoenix software.
** Set ArcGlide plasma inputs to dry (D) using the plasma input switch on the THC processor board in the control module.
* Multiple wires are the same color. Verify pin-to-pin connections before plugging cables into equipment.
** ArcGlide interlock must be closed to enable ArcGlide motion.