4 – Maintenance
• The lifter interface cable is
damaged.
• Examine the lifter interface cable for
damage.
36
HYPERNET
ADDRESSING
The number of Hypernet
packets that dropped
out exceeded the
maximum number.
• The Hypernet components are
not addressed correctly.
• The Ethernet cable is loose or
damaged.
• Verify that the unit addresses on all the
Hypernet devices on each station have
the same unit address.
• Examine all Ethernet cable connections.
• Examine all Ethernet cables for damage.
37
SOFTWARE FAILURE
• The microprocessor cannot be
programmed.
• Restart the ArcGlide control module.
• Contact your table manufacturer to
replace the THC processor board
(228578) in the control module.
38
SOFTWARE LOOP
TIME
The 10 ms control loop
time was exceeded.
• The Ethernet cable is loose or
damaged.
• Examine all Ethernet cables and cable
connections to verify that they are not
damaged or loose.
• Spare input 2 on the CNC is
being used.
• Spare input 2 is reserved for factory use
only. Do not use Spare input 2.
• Electrical interference can
occur when the ArcGlide and
drives are sharing power.
• Isolate electrical noise between
ArcGlide and drive power.
• Check for low line voltage.
39
SOFTWARE UNDEF
DISPLAY
There’s an invalid value
on the Diagnostics
screen.
• The THC processor board in
the control module is not
operating correctly.
• Contact your local Hypertherm
Technical Service representative to
replace the THC processor board or
update the ArcGlide firmware.
40
SOFTWARE ANALOG
INPUT
An invalid input channel
was selected.
• Pins on a cable connector are
not transmitting the expected
signal.
• Examine all of the cable connections on
the control module.
41
PROTOCOL
MISMATCH
• Software versions are not the
same in all of the units that are
connected to Hypernet.
• Turn ON power to the CNC, plasma
system, ArcGlide HMI, and control
module then update the ArcGlide
firmware. See
firmware on page 180 for instructions.
42
LOST PAC HYPERNET
The ArcGlide control
module lost the
Hypernet connection to
the plasma system.
• The Hypernet cable is
disconnected between the
control module, the Ethernet
switch, and the plasma system.
• Verify that the plasma system is
turned ON
• Examine all Hypernet connections.
Error
Description
Causes
Solutions