Hypertherm THC ArcGlide User Manual
Page 286
286
ArcGlide THC Instruction Manual 806450
B – ArcGlide THC Serial Communication Installation
Plasma I/O split cable (Y) (223262), continued
Connector A
Pin No.
Wire color
Signal
Connector B
Pin No.
1
Not connected
1
2
Not connected
2
3
Not connected
3
4
Not connected
4
5
Not connected
5
6
Black
Motion input +
6
7
8
Blue
Black
Input common -
Error input +
7
8
9
10
Yellow
Black
Input common -
Rampdown Error input +
9
10
11
12
Brown
Black
Input common -
Not Ready input +
11
12
13
14
Orange
Black
Input Common -
Serial enable +
13
14
15
16
White
Red
Input common -
Corner output A
15
16
Connector A
1
4
5
10
16
23
29
34
9
15
22
28
33
37
Connector B
1
5
10
16
23
29
34
4
9
15
22
28
33
37