211
4 – Maintenance
ArcGlide PCBs
HMI processor board (228581)
In a Hypernet configuration, the Unit address switch (SW6) on the HMI processor board
must have the same address as the Unit address switch on the THC processor and the
Hypernet plasma interface boards. The default setting is 1.
Test points
Test point No.
Signal
TP10
+2.5 VDC
TP33
+3.3 VDC
TP37
+5 VDC
TP38
Ground
J4 LCD character module
Pin No.
Signal
Pin No.
Signal
1
DB6
2
DB7
3
DB4
4
DB5
5
DB2
6
DB3
7
DB0
8
DB1
9
WR\
10
E1 (lines 1 and 2)
11
Vee
12
RS
13
VOC
14
Vss
15
Not connected
16
E2 (lines 3 and 4)