ArcGlide THC Instruction Manual 806450

4 – Maintenance

18

ERR SAMPLE ARC
VOLTAGE

With Sample Voltage ON,
the arc voltage samples
from cut to cut were out of
the sample range. This
error can occur if the arc
voltage sample on the next
cut is not within a given
range from the voltage
sample of the previous cut.
For example, if the sample
voltage of the previous cut
was 120 VDC and the
sample voltage of the next
cut is 170 VDC, cutting
stops and the error
displays. The IHS at the
next pierce point could not
be performed accurately.

• The lifter is stalling before

reaching the workpiece.

• Perform an IHS test and verify that the

torch is retracting to the transfer height
accurately.

• The Stall Force is set too high. (Nozzle

Contact is OFF.)

• If the problem continues and cut quality

is affected, disable Sample Voltage
mode and see if the cut quality improves.

• There is slag build-up on the

bottom of the shield.

• Examine the shield for slag build-up.

• The workpiece is not lying flat

on the table.

• Verify that the workpiece is lying flat and

not warping while cutting. If so, set
Nozzle Contact Cutting to OFF in the
Plasma Process screen.

• The consumables were

changed and the consumable
counter in the ArcGlide was not
reset.

• The consumables are damaged.

• The wrong consumables are in

the torch or the plasma system
is using the wrong cutting
process.

• Verify that the consumable life counter

on the ArcGlide was reset after
changing the consumables.

• Examine the consumables for damage,

and verify that the cutting process is
correct.

• There is a problem with plasma

system.

• Verify that the plasma system does not

have any gas leaks or restrictions.

Error

Description

Causes

Solutions