Hypertherm THC ArcGlide User Manual
Page 226
226
ArcGlide THC Instruction Manual 806450
4 – Maintenance
Pins 11 and 12 on connector J3 must be connected to locations 1 and 3 on terminal block 2 in an HPR plasma system.
The arc voltage terminals on connector J4 must be connected to the I/O board in an HPR plasma system.
J3 (Relay contact outputs from the THC to a generic plasma system)
Pin No.
Signal
Pin No.
Signal
1
Corner A
2
Corner B
3
Pierce A
4
Pierce B
5
Hold A
6
Hold B
7
Plasma start A
8
Plasma start B
9
Spare THC out A
10
Spare THC out B
11
Remote ON A
12
Remote ON B
13
Common
14
Common
15
+24 V output
16
+24 V output
J4 Arc voltage
Pin No.
Signal
1
Electrode -
2
Work +
J3
Connect pins 11 and 12
to locations 1 and 3 on
terminal block 2 in an
HPR plasma system
Connect the arc voltage
terminals to the I/O
board in an HPR plasma
system.
J2
J4