beautypg.com

Arcglide thc in a new installation – Hypertherm THC ArcGlide User Manual

Page 275

background image

ArcGlide THC Instruction Manual 806450

275

B – ArcGlide THC Serial Communication Installation

ArcGlide THC in a new installation

Figure 50 shows an ArcGlide THC in a new installation with a third-party CNC. In this configuration, the extended set of
ArcGlide THC features are available to third-party CNCs with the ArcGlide extensions to the basic Command THC serial
protocol.

New configurations with a Hypertherm CNC must use Hypernet for communication. For more information, refer to the
illustration in

Connecting cables in a new serial system on page 278.

Figure 50

CNC I/O cable, for discrete signals

Serial cable, for
serial signals

Customer-supplied operator
console
(optional):
- Station on/off/program switch
- Station active lamp
- Lifter UP/DOWN switch

CNC

ArcGlide lifter

ArcGlide control module

Plasma I/O cable, for arc
voltage and discrete
signals

Plasma system

HMI (optional)

Key:

Hypernet connection

– – – – – ––

Discrete connection

———————

Serial connection

- - - - - - - - - -