Hypertherm THC ArcGlide User Manual
Page 69

ArcGlide THC Instruction Manual 806450
69
2 – Installation
7 – ArcGlide THC with discrete communication to a Picopath interface CNC and HSD130 plasma system
Electrode -
Work +
Arc voltage sense wires to plasma system, use ~0.9 mm
2
(18 AWG) twisted pair wire,
rated 600 V or greater.
Optional ArcGlide HMI
Rotary address switch, set to 1
Shielded Ethernet cable, up
to 61 m (200 feet) long
Lifter I/O cable
ArcGlide control module
ArcGlide THC lifter
DB50 (male)
Rotary address switch, set to 1
Plasma I/O cable
CNC I/O cable
See the table in the drawing on page 73 for information about
wiring Picopath I/O.
Plasma interface board (141094), mounted externally by the customer
Interface cable 123209
1.5 m (5 feet)
Discrete plasma interface
board (141094)
HSD130
CNC with Picopath interface
DB37
Axes 1, 2
I/O
Axes 3, 4