Non-serial plasma interface cable – Hypertherm THC ArcGlide User Manual
Page 115

ArcGlide THC Instruction Manual 806450
115
2 – Installation
Non-serial plasma interface cable
This cable connects the ArcGlide plasma interface board and control board inside the plasma system. Use this cable only
when the CNC provides serial communication directly to the control board.
Part number
Length
Used in
223192
0.61 m (2 feet)
HPR130XD, HPR260XD
223193
2.3 m (7.5 feet)
HPR400XD
Pin No.
Color
Signal
Pin No.
Color
Signal
1
Not connected
20
Not connected
2
Not connected
21
Not connected
3
Black
RS-422 communication
22
Blue
HPR turned ON
4
Black
Motion -
23
Yellow
Motion +
5
Black
Error -
24
Brown
Error +
6
Black
Rampdown error -
25
Orange
Rampdown error +
7
Red
HPR not ready -
26
White
HPR not ready +
8
Red
Not connected
27
Green
Not connected
9
Red
Not connected
28
Blue
Not connected
10
Red
Not connected
29
Yellow
Not connected
11
Red
Not connected
30
Brown
Not connected
12
Red
Corner A
31
Orange
Corner B
13
Green
Pierce A
32
White
Pierce B
14
Green
Hold A
33
Blue
Hold B
15
Green
Plasma Start relay A
34
Yellow
Plasma Start relay B
16
Green
Remote ON A
35
Brown
Remote ON B
17
Green
Not connected
36
Orange
Ground
18
White
Ground
37
Black
+24 VDC HPR plasma
19
Blue
Not connected
38
Ground
Red band
Diameter = 13.72 mm (0.54 inch)
Bend radius = 152.40 mm (6.00 inch)