Discrete plasma interface board (141094) – Hypertherm THC ArcGlide User Manual
Page 90
90
ArcGlide THC Instruction Manual 806450
2 – Installation
Install the plasma interface board in a plasma system
The plasma interface board includes the voltage divider and allows the ArcGlide THC to communicate with the plasma
system.
If you are replacing a Command THC with an ArcGlide THC, you must replace the Command THC plasma interface
board in your plasma system with an ArcGlide plasma interface board.
Discrete plasma interface board (141094)
The discrete plasma interface board is mounted in an enclosure that is installed in your plasma system, either internally or
externally. For specific instructions and safety-related information about mounting the enclosure, refer to the manual that
came with your plasma system.
Figure 23
See
Discrete plasma interface board (141094) on page 224 for information about electrical installation.
152.40 mm
(6.00 inch)
114.30 mm
(4.50 inch)