2 – installation – Hypertherm THC ArcGlide User Manual
Page 106
![background image](https://www.manualsdir.com/files/789505/content/doc106.png)
106
ArcGlide THC Instruction Manual 806450
2 – Installation
All ArcGlide CNC inputs can be configured for dry contact closures or 12 – 24 V sourced inputs.
Pin No.*
Color
Signal name
Dry contact
circuit (D)
Sourced circuit
(S)
1
Red
Cycle Start input +
2
Black
Cycle Start input -
3
White
Low Gain input +
4
Black
Low Gain input -
5
Green
AVC
**
Disable input +
6
Black
AVC
**
Disable input -
7
Blue
IHS Sync input +
8
Black
IHS Sync input -
9
Yellow
Spare input 1 +
10
Black
Spare input 1 -
11
Brown
Spare input 2 +
12
Black
Spare input 2 -
*
Pin numbers are the same on both ends of the cable.
**
AVC = Arc voltage control
+24 V
3.9 K
3.9 K
3.9 K
+24 V
3.9 K
3.9 K
3.9 K
+24 V
3.9 K
3.9 K
3.9 K
+24 V
3.9 K
3.9 K
3.9 K
+24 V
3.9 K
3.9 K
3.9 K
+24 V
3.9 K
3.9 K
3.9 K