beautypg.com

Hypertherm THC ArcGlide User Manual

Page 96

background image

96

ArcGlide THC Instruction Manual 806450

2 – Installation

2. Connect the CNC to the control module:

a. Insert the end of the CNC I/O cable with the yellow band into the

CNC I/O connector on the front of the control module.

b. Connect the wires on the other end of the cable to the I/O signals on

the CNC.

See

CNC I/O cable on page 105 for more information.

3. Connect the plasma system to the control module:

a. Insert the end of the plasma interface I/O cable with the blue band

into the Plasma I/O connector on the front of the control module.

b. Connect the other end of the cable into the plasma I/O connector

(J5) on the plasma interface board in the plasma system.

See

Plasma interface I/O cable on page 110 for more information.

4. If your configuration includes a, optional, customized operator console,

connect it to the control module:

a. Connect the end of the operator console I/O cable with the green

band into the operator console I/O connector on the front of the
control module.

b. Connect the other end of the cable into the appropriate connectors

on the custom operator console.

See

Optional operator console I/O cable on page 101 for more information.

5. See Install the lifter on page 77 for more information on connecting the

ArcGlide lifter to the control module.

Discrete connection to the CNC

Discrete connection to the plasma
system

Connection to the operator
console

Connection to the lifter