Hypertherm THC ArcGlide User Manual
Page 83
ArcGlide THC Instruction Manual 806450
83
2 – Installation
7. Install the air supply to the filter/regulator inlet port at 6.9 bar (100 psi), the recommended pressure.
8. Adjust the filter/regulator to indicate 2 bar (30 psi), the recommended starting pressure, on the gauge. Typical
operating pressure is 2.75 bar to 4 bar (40 psi to 60 psi)
9. Simulate a crash by forcing the breakaway to separate by hand.
10. Manually reposition the breakaway in the locked position.
11. Adjust the air pressure until the desired trip force is achieved.
12. Enable the emergency stop circuit at the CNC after the breakaway is installed.