Hypertherm THC ArcGlide User Manual
Page 262

262
ArcGlide THC Instruction Manual 806450
A – ArcGlide THC Serial Communication Protocol
IHS Speed
Command ID
Data
Examples
IS
10 – 150 in/min
254 – 3,810 mm/min
>IS6002< IHS Speed set to 60 in/min.
>IS152468< IHS Speed set to 1,524 mm/min.
>IS?DB< Inch or metric query from the CNC.
Sets the slow speed for the final approach to the workpiece during an IHS operation and the slow speed for
manual moves.
Default: 1,524 mm/min or 60 in/min
Use the default when using the Hypertherm lifter with the ArcGlide.
Speed Gain
Command ID
Data
Examples
SG
1 – 10 (1 = lowest gain)
>SG5CF< Speed Gain set to 5.
>SG?D9< Query from the CNC.
This gain value regulates the speed gain of the lifter.
Default: 5
Use the default when using the Hypertherm lifter with the ArcGlide.
Position Gain
Command ID
Data
Examples
PG
1 – 10 (1 = lowest gain)
>PG5CC< >PG05FC< Either command sets
Position Gain to 5.
>PG?D6< Query from the CNC.
This gain is used for closed loop positioning.
Default: 5
Use the default when using the Hypertherm lifter with the ArcGlide.