Pump Control Unit

Pump Interface Manual v1.3

Gasboy CFN Series

03/20/03

DIP Switch Bank C

Note: In connection with pulser enabled, there are two error codes, each with three characters,
that can show up in the error column on a transaction printout. The reset-failed-to-start
transaction code is $D2 through $DF, and the reset-failed-to-complete transaction code is $E5
through $EF ($ indicates hexadecimal). The last character in each code (2 through F or 5 through
F) is the number of seconds the PCU waited for reset to start or complete. This numeric character
is incremented by one each time the PCU reset-to-start/complete times out, until the maximum
time-out of 15 (15 is F in hexadecimal counting) seconds is reached.

Test Mode. When test mode is activated with switch C-8, switch C-5 determines the relay limits:

In test mode, switches C-6 and C-7 select the pump to be tested:

Address

B-1

B-2

B-3

B-4

1

cl

cl

cl

cl

2

op

cl

cl

cl

3

cl

op

cl

cl

4

op

op

cl

cl

5

cl

cl

op

cl

6

op

cl

op

cl

7

cl

op

op

cl

8

op

op

op

cl

9

cl

cl

cl

op

10

op

cl

cl

op

11

cl

op

cl

op

12

op

op

cl

op

13

cl

cl

op

op

14

op

cl

op

op

15

cl

op

op

op

16

op

op

op

op

Position & Definition

Setting(*=customary)

1-4

pulser enabled (pumps
1-4)
(see note below)

closed=after reset is
complete
open=upon activation

5

____

6

dead man timer

*always open=enabled

7

____

8

test mode

*closed=no
open=yes

C-5

Function

open

pump slows at 500 pulses and turns off at 510 pulses

closed

pump slows at 50 pulses and turns off at 60 pulses

Pump to Test

C-6

C-7

1

closed

closed

2

open

closed

3

closed

open

4

open

open