3 insight interface - cfn3 only, Setup for nt based application using sc3 program, Hardware connections – Gasboy CFN Site Controller User Manual
Page 23: Insight interface - cfn3 only

Pump Interface Manual v1.3
Insight Interface - CFN3 only
15
03/20/03
Gasboy CFN Series
3
Insight Interface - CFN3 only
NOTE: Insight is available on CFN3 only. This chapter is valid for Insight driver version
2.0Bx13 and above.
Setup for NT based application using SC3 program
The site setup and configuration are the same as when using a DPT except as noted in this
document. The reader type in the reader configuration is DPT. The Site Controller considers the
Insight a newer version of the DPT. For the site controller setup refer to the CFN3 Configuration
and Managers manuals that came with this system. Setup your keyboard layout in Sys_Par
according to the Site Controller Configuration Manual, page 4.
This requires SC3 to PC version 1.0Bx8 or above, CFN3 version 3.0B or above, and Insight
MTPQ0500 or additional versions when certified by Gasboy. The use of broadcast messages or
the use of keypad entered look-up (numeric) numbers are currently not supported.
Hardware Connections
Connect Com1 (default) or alternate PC Com port to the DB25 connector of the 9600 converter
(Gasboy part# C05859). Use a standard PC DB9 to DB25 cable (part# C06253). The following
is an overview of the connections and a wiring illustration:
Connect the power supply (part# C05440) to the 9600 converter and plug it in.
Tokheim 69 Box
CFN
3
Com1
C05859
9600
Converter
Tokheim Insight
P2 Connector
Site J1
(for multiple connections)
J2, J3, J4, J5
PMR-C Junction Box
-485 4
+485 3
GND 2
GND 1
1
2
3
4
4
3
2
1
5 -485 Red
4 +485 White
6 DCC Black
(See NOTE)
NOTE:
Connections for Premier B are
3, 1, and 5 instead of 5, 4, and 6.
DB9-DB25 CABLE
C06253