Pump Interface Manual v1.3

Wayne

43

03/20/03

Gasboy CFN Series

option, define 3 hoses only and the Wayne pump driver maps them to the appropriate
pump positions automatically.

Site Controller Pump Configuration

In the PUMP configuration program, in submenu 3, set the following options:

Note: Set option 23 for models V580 and V590U if using SCII version 2.3 and CFN3

version 3.3 only.

Considerations when loading Site information

1.

The Wayne controller must be set at 1200 baud.

2.

When a dispenser has been authorized, fuel can be dispensed from any hose on
that dispenser.

3.

All pulser units, limits, etc., must be in the same units (gallons or dollars) in both
the pump configuration and in the loadable commands.

4.

Limits and cutoffs should be loaded in gallons in order for the dispenser presets to
work properly. If the dispensers have the Cash/Credit feature, the limits must be
loaded for $999.

5.

Club cards that have a price level higher than 2 cannot be preset in $$$.

6.

The dispensers can only display price levels 1 or 2. The $TOTAL will be
recalculated if other price levels are used.

7.

Price level 2 (credit) must be loaded in order for the dispenser to work and must
contain the same price as loaded in price level 0.

8.

The price loaded in price level 1 (cash) must be less than or the same as the price
loaded in price level 2 (credit).

9.

Wayne dispensers can be assigned price codes in the ranges of 1-9 (with 6-9
reserved for blends), 11-19 (16-19 reserved for blends), 21-29 (26-29 reserved for
blends), and 31-39 (36-39 reserved for blends). There are several restrictions as
follows:

Requires a FRAMOS.BIN file on the Release disk that has a date of 11/10/93
or later (for systems with a FRAMOS.BIN file dated prior to 11/10/93, see
below).

For Site Controllers with a FRAMOS.BIN file dated prior to 11/10/93:

Only price codes 1-9 may be used, with 6-9 reserved for blenders.

If a pump is assigned a price code higher than 9 or equal to 0, the dispenser
will display the price loaded in price code 1, level 1 or 2. The $TOTAL will be
recalculated and the transaction $TOTAL will reflect the correct price.

Wayne type

Options to set

Wayne MPD

1,2,5,7,9

Wayne MPD $/Cr

1,2,3,5,7,9

Wayne Blender

1,2,5,7,9,12

Wayne Blender $/Cr

1,2,3,5,7,9,12