Pump Interface Manual v1.3
Islander II
37
03/20/03
Gasboy CFN Series
Splitter Cabling
NOTES:
1.
Use a C05578 cable for connection to a single 67 or 98 Interface box. Use a
C05876 cable for connection to two 67 or 98 Interface boxes. Both cables include
the Tokheim Splitter.
2.
A Model 180 signal cable extension is available as an accessory from Tokheim.
The maximum distance of the combined cables and field wiring should not exceed
350 feet. The maximum distance for a 98 Interface box is 250 feet.
3.
Use part number C06694 for connection to three or more 98 Interface boxes.
C06694 is the combination of one C05878 cable, two C05577 cables and a
Tokheim Splitter.
4.
Communication for pumps 1-32 may be provided through port 1 or 3 of the
Islander II.
5.
The second two 98 boxes must be connected to channel 2 of the splitter. Address
the third 98 box (first 98 box on channel 2) as pumps 1 to 8; address the fourth 98
box (second 98 box on channel 2) as pumps 9 to 16.
WIRING TO PORT 1
OR PORT 3
TOKHEIM SPLITTER
C05578 OR C05876
APPROX. 12 FT. CABLE
(SEE NOTE 1)
APPROX. 12 FT. CABLE
FROM COMPUTER MODULE
(SEE NOTE 2)
CONNECTOR OR
TERM. BOX
MODEL 67/98
INTERFACE BOX
MODEL 67/98
INTERFACE BOX
WIRING TO PORT 1
OR PORT 3
C05851
TOKHEIM
SPLITTER
C05878
APPROX 1 FT.
CABLE
C05577
APPROX 12 FT. CABLE
C05577
APPROX 12 FT. CABLE
APPROX. 12 FT. CABLE
FROM COMPUTER MODULE
(SEE NOTE 2)
APPROX. 12 FT. CABLE
FROM COMPUTER MODULE
(SEE NOTE 2)
CONNECTOR OR
TERM. BOX
MODEL 98 SERIES
COMPUTER MODULE
PUMPS 1-8
MODEL 98 SERIES
COMPUTER MODULE
PUMPS 9-16
PUMPS 17-24
PUMPS 25-32
MODEL 98 SERIES
COMPUTER MODULE
MODEL 98 SERIES
COMPUTER MODULE
SEE
NOTE
5
CHANNEL
1
CHANNEL
2
(SEE NOTE 3)