Sdi box switches, Sdi led display – Gasboy CFN Site Controller User Manual
Page 59

Pump Interface Manual v1.3
SDI/Wayne CAT Interface
51
03/20/03
Gasboy CFN Series
The numbers of the keypad keys on the CAT are:
Note that keys on the left half of the keyboard - that is: 1, 2, 3, 6, 7, 8, 11, 12, 13, 16, 17, and 18
- cannot be changed..
The default function arrangement of the CAT keypad is:
The string that would be typed into the Tokheim/DPT/Wayne CAT keyboard layout item in
SYS_PAR to give the CAT keypad function arrangement shown above is:
123ub456$B789NYC0EHX
Refer to the SCII or CFN3 Configuration Manual for more information.
SDI Box Switches
The SDI box contains a switch for setting the SDI box number and for clearing the unit’s
memory. Switch functions are:
MODA/MODB are on switch 7, RESET on switch 8.
For Wayne CAT, SDI #1, make all switches to OFF (open).
For Wayne CAT, SDI #2, make position 5 ON (closed), all others OFF (open).
To clear application memory:
(Do this under instruction from qualified support engineer only)
1.
Close switch position 6
2.
Close switch position 8
3.
Open switch position 8
4.
Wait a few seconds
5.
Open switch position 6
SDI LED Display
The SDI unit has a single LED located next to the switch assembly. This LED is used to display
the status of the SDI unit and the Wayne CAT units. The LED display consists of a series of
blinks and delays that show the site status. SDI unit status is shown using a slow or fast blinking
LED with no delay between blinks. SDI run time status is shown by a series of 1 to 4 blinks in a
group followed by a delay between groups. The display codes are:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
u
b
4
5
6
$
B
7
8
9
N
Y
C
0
E
H
X
1
2
3
4
5
6
7
8
ADDR ADDR
ADDR
ADDR
ADDR
DLD
MODA
RESET
4
3
2
1
0
MODB