Cfn3 cabling, Scii and cfn3 configurations, Sys_par.bin, page 8 – Gasboy CFN Site Controller User Manual

Page 49

background image

Pump Interface Manual v1.3

Wayne

41

03/20/03

Gasboy CFN Series

The SCII K1 (port 1) or K2 (port 3) jumper patch must be configured for a Wayne port.

Below is the system layout for the Wayne interface and a SCII.

K2 Jumper Settings.

CFN3 cabling

The Wayne 2400 Controller is connected to either ports 4, 5 or 6 of the CFN3 with a C06006
cable. The cable comes in 8 ft lengths. The maximum distance for this cable is 100 ft.

SCII and CFN3 Configurations

SYS_PAR.BIN, page 8

In SYS_PAR.BIN (page 8), the “Special pump handler channel” parameter must be configured
for the ports listed under cabling for either the SCII or CFN3 (see previous sections).

Male DB-25P

Connector

Female DB-
25S
Connector

2

2

3

3

4

4

5

5

6

6

7

7

8

8

20

20

Site Controller II

Wayne
2400
Site Controller

Wayne Cable
C04654

To pumps/dispensers

Interface cable must be plugged into port 3 or port 1
of the Site Controller II