Front panel leds, Interface board, Site controller configuration – Gasboy CFN Site Controller User Manual
Page 37

Pump Interface Manual v1.3
Gilbarco Interface Unit
29
03/20/03
Gasboy CFN Series
Front Panel LEDs
L1 L12
o o o o o o o o o o o o
CPU
o o o
Current Loop PCB
DC BOK BAD
Interface Board
Site Controller Configuration
Site Controller I
Site Controller I version 4.0 software and above will work with Gilbarco pumps.
Normally the Site Controller I is configured at the factory for the pump types. The pump types
are configured at TABLE 24, OFFSET 18+(PMP#-1)x4. Refer to the Site Controller I Technical
Manual to help understand the following CONFIGS.
a) 2 sided, 1 hose per pump. Byte = 64
b) 1 sided, 1 hose per pump. Byte = 74
c) 2 sided, 2 hose per pump. Byte = 65
d) 1 sided, 2 hose per pump. Byte = 75
e) 2 sided, 3 hose per pump. Byte = 66
f) 1 sided, 3 hose per pump. Byte = 76
Note: SC I will not work with multi hose unit.
Lamp
Indication
L1
transmit data on CRIND 422/485 port
L2
receive data on CRIND 422/485 port
L3
transmit data on 422/485 loop #1
L4
receive data on 422/485 loop #1
L5
dead man timer refresh
L6
current loop power enabled
L7
current loop #1 active if flashing
L8
current loop #2 active if flashing
L9
program crash code bit 1
L10
program crash code bit 2
L11
program crash code bit 3
L12
program crash code bit 4
DC
DC 5V power OK (green)
BOK
battery OK (green)
BAD
battery bad (red)
Jumper
Function and/or Normal Setting
K1
Baud rate clock source; must be installed in position 1.
K2
Battery backup enable. Boards should be stored with this
jumper out; it should be installed at assembly time. Lamp
BAD will light if K2 is omitted.