SDI/Wayne CAT Interface

Pump Interface Manual v1.3

Gasboy CFN Series

03/20/03

The first display in the self test shows:

REV XXX XX/XX/XX
ADDRESS = XX

The top row is the Vista Card terminal software revision level and the bottom row is the

currently assigned terminal address for the card processing terminal communication data link.
The top line must display the revision level of 50 or greater.

Press

to

exit.

Follow the instructions in the manual Installation Operation, Vista Series from Wayne

Dresser for completing the self test.

Site Controller Software Configuration

Version 2.2 or later of the SCII or version 3.0 or later for the CFN3 software is required to run a
Wayne CAT. The CAT should be on the RS-422 port.

All readers that are to be CATs must be set up in the Reader configuration to be device type

Wayne CAT. The Reader Parameter “TYPE” (device type) must be changed to 8, for Wayne
CAT.

Reader Addresses

No reader can be set to the address of 30, that is reserved for the Master Security Module. The
reader that would have been 30, give the address of 40. The Site Controller will read the address
as 30.

Keypad

The keys of the CAT keypad can be configured for different functions with the Tokheim DPT/
Wayne CAT keyboard layout item on page 4 of the Site Controller’s SYS_PAR program. The
characters that select different functions are shown below. Note that these characters are case-
sensitive:

Character

Function

0-9

Numeric digits 0-9

.

Decimal point

E

ENTER

C

CLEAR

Y

Yes

N

No

$

Cash inside

c

Cash outside

D

Debit inside

d

Debit outside

B

Credit (bank card inside)

b

Credit outside

X

CANCEL

x

CLEAR/CANCEL (CLEAR if data entry started; else CANCEL)

H

Help

h

Help/Decimal (Decimal if data entry started; else Help)

n

No/CANCEL (No if in yes/no state; else CANCEL)

S

Start

u

unused key

ENTER