Insight board switches – Gasboy CFN Site Controller User Manual
Page 24

16
Insight Interface - CFN3 only
Pump Interface Manual v1.3
Gasboy CFN Series
03/20/03
Insight Board Switches
SW1 on the Insight board is used to set the Insight address and baud rate for the site controller
port.
Leave position 1 and 2 alone. These control internal settings for the Insight/pump interface,
which should be set at the factory or by a Tokheim service person. Set each Insight address to
match the site’s DPT address. These are set using positions 3-7.
Set position 8 to OFF for 9600 baud.
3
4
5
6
7
address
ON ON
ON
ON
ON
1
OFF ON
ON
ON
ON
2
ON
OFF ON
ON ON
3
OFF
OFF
ON
ON
ON
4
ON
ON
OFF
ON
ON
5
OFF
ON
OFF
ON
ON
6
ON
OFF
OFF
ON
ON
7
OFF
OFF
OFF
ON
ON
8
ON
ON
ON
OFF
ON
9
OFF
ON
ON
OFF
ON
10
ON
OFF
ON
OFF
ON
11
OFF
OFF
ON
OFF
ON
12
ON
ON
OFF
OFF
ON
13
OFF
ON
OFF
OFF
ON
14
ON
OFF
OFF
OFF
ON
15
OFF
OFF
OFF
OFF
ON
16
ON
ON
ON
ON
OFF
17
OFF
ON
ON
ON
OFF
18
ON
OFF
ON
ON
OFF
19
OFF
OFF
ON
ON
OFF
20
ON
ON
OFF
ON
OFF
21
OFF
ON
OFF
ON
OFF
22
ON
OFF
OFF
ON
OFF
23
OFF
OFF
OFF
ON
OFF
24
ON
ON
ON
OFF
OFF
25
OFF
ON
ON
OFF
OFF
26
ON
OFF
ON
OFF
OFF
27
OFF
OFF
ON
OFF
OFF
28
ON
ON
OFF
OFF
OFF
29
OFF
ON
OFF
OFF
OFF
30
ON
OFF
OFF
OFF
OFF
31
OFF
OFF
OFF
OFF
OFF
32