beautypg.com

Cabling, D-box to gilbarco interface – Gasboy CFN Site Controller User Manual

Page 40

background image

32

Gilbarco Interface Unit

Pump Interface Manual v1.3

Gasboy CFN Series

03/20/03

The numbers of the keypad keys on the CRIND are:

Note that keys on the left half of the keyboard—that is, 1, 2, 3, 6, 7, 8, 11, 12, 13, 16, 17, and
18—cannot be programmed.

The default function arrangement of the CRIND keypad is:

The string that would be typed into the Tokheim DPT/Gilbarco CRIND keyboard layout item in
SYS_PAR to give the CRIND keypad function arrangement shown above is:

123ub456$B789NYC0EHX

Cabling

D-Box to Gilbarco Interface

Interface to D-Box Current Loop Wiring - Pump Loop

Part number: C06691.

Character

Function

0-9

Numeric digits 0 through 9

.

Decimal Point

E

ENTER

C

CLEAR

Y

yes

N

No

$

Cash inside

c

Cash outside

D

Debit inside

d

debit outside

B

Credit (bank card) inside

b

Credit (bank card) outside

X

Cancel

x

CLEAR/CANCEL (CLEAR if data entry started; else CANCEL)

H

Help

h

Help/Decimal (Decimal if data started; else Help)

n

No/CANCEL (No if in yes/no state; else CANCEL)

S

Start

u

unused key

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

1

2

3

u

b

4

5

6

$

B

7

8

9

N

Y

C

0

E

H

X