Gasboy CFN Site Controller User Manual
Page 18

10
Tokheim
Pump Interface Manual v1.3
Gasboy CFN Series
03/20/03
•
SW1, position 1 is not used for releases prior to 1.0D of the Gasboy DPT program.
For release 1.0D and above, SW1, position 1 is set to OFF if the printer has a cutter bar;
ON if the printer has a tear bar.
•
SW1, position 2 determines the UDC poll address for the Premier pump head. SW1,
position 2 must be set to On for side A and OFF for side B.
•
The Premier Pump head address is set in mode 23.
•
SW1, positions 3-7 indicate the address for the DPT. Use the following table to set the
address.
•
SW1, position 8 controls the line display. ON for 4-line display and OFF for 2-line dis-
play.
Tokheim 69 box
A Tokheim 69 box is used for wiring a DPT to a CFN2 or CFN3. The DPTs are wired from J2
through J5 in the 69 box. The GASBOY RS-422/485 J-Box is wired to J1 of the 69 Box. If the 69
Address
1-7
1-6
1-5
1-4
1-3
1
on
on
on
on
on
2
on
on
on
on
off
3
on
on
on
off
on
4
on
on
on
off
off
5
on
on
off
on
on
6
on
on
off
on
off
7
on
on
off
off
on
8
on
on
off
off
off
9
on
off
on
on
on
10
on
off
on
on
off
11
on
off
on
off
on
12
on
off
on
off
off
13
on
off
off
on
on
14
on
off
off
on
off
15
on
off
off
off
on
16
on
off
off
off
off
17
off
on
on
on
on
18
off
on
on
on
off
19
off
on
on
off
on
20
off
on
on
off
off
21
off
on
off
on
on
22
off
on
off
on
off
23
off
on
off
off
on
24
off
on
off
off
off
25
off
off
on
on
on
26
off
off
on
on
off
27
off
off
on
off
on
28
off
off
on
off
off
29
off
off
off
on
on
30
off
off
off
on
off
31
off
off
off
off
on
32
off
off
off
off
off