2.3.4.1.1 Control Interfaces

There are five control inputs as follows:

AC Power ON (Pin a).
Connect Pin a to ground (Pin Z) to enable operation of the amplifier and turn the
TWT heater on.

C AU TIO N

The AC control circuit does not affect the connection of the power
amplifier to prime power. Disconnect Prime Power when the power
amplifier is serviced.

High Voltage Enable (Pin F).
Connect Pin F to ground (Pin W) to turn high voltage on.

Heater Standby (Pin J).
Connect Pin J to ground (Pin W) to reduce the voltage applied to the TWT
heater. This feature is provided to extend the life of the TWT when the amplifier
is the back-up unit in a redundant configuration. The High Voltage ON overrides
the Heater Standby command and returns the TWT heater voltage to normal
operating value.

Fault Reset (Pin X).
Momentarily connect Pin X to ground (Pin W) to reset the high voltage fault and
helix current fault.

Note: Turning the High Voltage OFF will also clear these faults.

AC Command Return (Pin Z).
Common return.

The external control inputs require +15 VDC pull-up. This is possible from the internal
+15 VDC of the amplifier or from an external DC supply. Both configurations are
described in the following paragraphs.

Using the Internal +15 VDC for Control, connect pin E to pin Y.

Using an External DC Supply for Control, connect pin Y to external +15V
source and source return to pin W.

Note: The EFData system harness is pre-wired to use the +15V output of the TWTA as
the input to the control pull-ups.