Controller for Redundant Systems

High-Power TWTA Satellite Terminals

6–6

Rev. 1

6.2.2.1.3 Manual/Automatic Push Button Switch

In either Local or Remote mode, the user can select manual switching or automatic
switching (Table 6-3). This switch alternately selects Manual mode or Automatic mode
each time the button is pressed. Manual switching is typically used for maintenance
operations, and automatic switching is used for routine operations. Manual switching can
be selected via the controller front panel or via a remote controller (when the controller
is set for Remote mode operation).

Table Chapter 6-3. Manual/Automatic Mode

Manual Mode

Manual mode is used for maintenance operations. When the redundant controller is
set for Manual operation, automatic switching is inhibited and channels can be
manually selected with the A/B channel select switches. This option can also be
selected in the Remote mode.

Automatic Mode

When the redundant controller is set for Automatic operation, and a fault of the
primary TWTA occurs, the system automatically places the faulted unit in the backup
position and the remaining unit in the primary position. The switchover takes place in
less than 100 milliseconds. The new connection is signaled by a corresponding
change in the redundant controller’s transfer switch position indicators.

When a TWTA fault occurs, the TWTA Status indicator of the faulted unit changes
from green to red.

In a warm-standby system, when a TWTA is switched from backup to primary
position, the redundant controller commands the high voltage of the switched unit to
ON.

Note: For hot-standby systems, the high voltage of both TWTAs is always ON.

If the backup TWTA is also faulted, the system will not switch units.

TWTA Power ON

Each TWTA can be powered up using the appropriate TWTA Power ON switch.