4 hpc-1110 installation, 1 mechanical – Comtech EF Data HPCST-5000 User Manual
Page 107

High-Power TWTA Satellite Terminals
Redundant System Installation
Rev. 1
3–23
3.4 HPC-1110 Installation
As part of the redundant system installation procedures, the TWTAs are installed and
tested before they are connected to the redundant system controller. The only
mechanically-critical item for the controller is locating and installing the cabinet slide
assemblies that support the controller in the rack.
3.4.1 Mechanical
An outline drawing of the HPC-1110 is shown in Figure 3-5.
Rear panel electrical connection requirements are determined by the insert options
incorporated into the unit.
There are five steps for mechanical installation of the controller:
1. Determine the location of the controller in the rack.
2. Install the cabinet slide assemblies in the rack.
3. Install the controller on the cabinet slide assemblies.
4. Install the front panel mounting screws to secure the controller in the rack.
5. If the controller options include RF input switching, install the necessary RF
input coaxial cables.