4 environment – Comtech EF Data HPCST-5000 User Manual
Page 41

High-Power TWTA Satellite Terminals
Introduction
Rev. 1
1-25
1.4.4 Environment
Note: RFT and TWTA are considered Outdoor Units (ODUs) and will appear as such
throughout this manual.
The maximum environmental conditions applicable to the ODUs are listed in Table 1-17.
Table 1-17. ODU Environmental Specifications
Environment
Conditions
Temperature
-40° to +50°C operating
-50° to +70°C survival, non-operating
Vibration
1.5g, 5 to 200 Hz and normal transportation levels
Shock
6g max.
Humidity
0
%
to 100
%
relative at -40° to +50°C
95
%
at 65°C for 72 hrs.
Precipitation
MIL-STD-810/Method 506.2
Salt Fog
MIL-STD-810/Method 509.2
Sand and Dust
MIL-STD-810/Method 510.1
Altitude:
Operational
Survival
0 to 10,000 ft.
0 to 40,000 ft.
Solar Radiation
360 BTU/hr/ft
2
at 50°C
Safety
TBD
Emissions
TBD
ES Discharge
10 kV operation, 15 kV survival
Note: HPCs are considered indoor units (IDUs) and appear as such throughout this
manual.
The maximum environmental conditions applicable to the IDUs are listed in Table 1-18.
Table 1-18. IDU Environmental Specifications
Environment
Conditions
Temperature
0° to +50°C operating
-10° to +70°C survival
Vibration and Shock
Normal transportation levels
Humidity
0
%
to 75
%
relative +50°C operating
95
%
at 50°C for 72 hr. non-operating
Altitude
0 to 10,000 ft.
Safety
TBD
Emissions
FCC Part 15, J, Class A