beautypg.com

4 environment – Comtech EF Data HPCST-5000 User Manual

Page 41

background image

High-Power TWTA Satellite Terminals

Introduction

Rev. 1

1-25

1.4.4 Environment

Note: RFT and TWTA are considered Outdoor Units (ODUs) and will appear as such
throughout this manual.

The maximum environmental conditions applicable to the ODUs are listed in Table 1-17.

Table 1-17. ODU Environmental Specifications

Environment

Conditions

Temperature

-40° to +50°C operating
-50° to +70°C survival, non-operating

Vibration

1.5g, 5 to 200 Hz and normal transportation levels

Shock

6g max.

Humidity

0

%

to 100

%

relative at -40° to +50°C

95

%

at 65°C for 72 hrs.

Precipitation

MIL-STD-810/Method 506.2

Salt Fog

MIL-STD-810/Method 509.2

Sand and Dust

MIL-STD-810/Method 510.1

Altitude:

Operational
Survival

0 to 10,000 ft.
0 to 40,000 ft.

Solar Radiation

360 BTU/hr/ft

2

at 50°C

Safety

TBD

Emissions

TBD

ES Discharge

10 kV operation, 15 kV survival

Note: HPCs are considered indoor units (IDUs) and appear as such throughout this
manual.

The maximum environmental conditions applicable to the IDUs are listed in Table 1-18.

Table 1-18. IDU Environmental Specifications

Environment

Conditions

Temperature

0° to +50°C operating
-10° to +70°C survival

Vibration and Shock

Normal transportation levels

Humidity

0

%

to 75

%

relative +50°C operating

95

%

at 50°C for 72 hr. non-operating

Altitude

0 to 10,000 ft.

Safety

TBD

Emissions

FCC Part 15, J, Class A