Redundant System Installation

High-Power TWTA Satellite Terminals

3–18

Rev 1

FLT_NC

FLT_NO
FLT_COM

EFD# CN/DSB09MSPT01

5

9

4

8

3

7

2

6

1

P6

DB9 MALE

G/-RXT

-RXT

+RXT

CTS/+R

RD/RX

RTS

TD/TX

DSR

485GND

EFD# CN/DSB09FSPT01

RS-232

RS-485

GND

CTS

RD/RX

RTS

TD/TX

DSR

GND

-RX/TX

-RX/TX

+RX/TX

+RX/TX

1

2

3
5

6

7

8

9

=

=

=

=

=

=

=

=

=

4

M&C SYSTEM

5

9

4

8

3

7

2

6

1

P5

DB9 FEMALE

SPARES

8

15

7

14

6

13

5

12

4

11

3

10

2

9

1

P2

DB15 MALE

1 = W/G SWITCH COMMON

2 = CH. A POSITION INDICATOR

3 = CH. B POSITION INDICATOR

8 = N/C

9 = N/C

7 = N/C

5 = N/C

6 = N/C

4 = N/C

W/G SW. #1

SPARES

M&C SYSTEM

G/-RXT

-RXT

+RXT

CTS/+R

RD/RX

RTS

TD/TX

DSR

485GND

B_HVEN

B_HSTBY

B_AGND

B_SYFLT

B_CSR
B_ACPON

A_HVEN

A_HSTBY

A_AGND

A_SYFLT

A_CSR
A_ACPON

HPA #A

HPA #B

A_HVON

A_FRST

A_+15V

B_HVON

B_FRST

B_+15V

B_HTC

A_HTC

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

EE

FF

GG

HH
JJ

II
KK

MM

NN

PP

QQ

RR

SS

TT

P1

EFD# CN/MS-STPG41M01

SHIELD

SPARES

W/G SW

H1ID1

HID1C
H2ID1

FLT_NC
FLT_NO

FLT_COM

B_SYFLT

19

37

18

36

17

35

16

34

15

33

14

32

13

31

12

30

11

29

10

28

9

27

8

26

7

25

6

24

5

23

4

22

3

21

2

20

1

P3

DB37 MALE

B_+15V

SPARES

A_SYFLT

A_+15V

H1ID1
HID1C

H2ID1

EFD# CN/DSB15MSPT01

10 = N/C

11 = N/C

12 = N/C

13 = N/C

14 = N/C

15 = N/C

19

37

18

36

17

35

16

34

15

33

14

32

13

31

12

30

11

29

10

28

9

27

8

26

7

25

6

24

5

23

4

22

3

21

2

20

1

P4

DB37 MALE

HPA #B CONTROL

SPARES

HIGH VOLTAGE ENABLE

HEATER TIMER COMPLETE
HEATER STANDBY

HIGH VOLTAGE ON

1

2

3

4

5

6

7

8

9

10

11

12

=

=

=

=

=

=

=

=

=

=

=

=

+15VDC in

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

HIGH VOLTAGE ENABLE

HEATER TIMER COMPLETE
HEATER STANDBY

HIGH VOLTAGE ON

1

2

3

4

5

6

7

8

9

10

=

=

=

=

=

=

=

=

=

=

HPA #A CONTROL

+15VDC in

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

DC POWER ON DETECT

SUMMARY FAULT

FAULT RESET

AC POWER ON

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

=

=

=

=

=

=

=

=

=

=

=

=

=

=

=

ANALOG RETURN

STATUS RETURN

UNUSED

UNUSED
UNUSED

UNUSED

UNUSED
UNUSED

UNUSED

UNUSED
UNUSED

A_HVEN

A_HSTBY

A_AGND

A_CSR

A_ACPON

A_HVON

A_FRST

A_HTC

EFD# CN/DSB37MSPT01

DC POWER ON DETECT

SUMMARY FAULT

FAULT RESET

AC POWER ON

13

14

15

16

17

18

19

20

21

22

23

24

25

=

=

=

=

=

=

=

=

=

=

=

=

=

ANALOG RETURN

STATUS RETURN

UNUSED

UNUSED

UNUSED
UNUSED

UNUSED

UNUSED
UNUSED

B_HVEN

B_HSTBY

B_AGND

B_CSR

B_ACPON

B_HVON

B_FRST

B_HTC

EFD# CN/DSB37MSPT01

Figure 3-2. HPCST/KST 1:1 Redundant M&C System Interface Cable (Optional) (CA/5279)