1 environmental requirements, Table 2-1, Environmental requirements – Artesyn MVME2500 ECC Installation and Use (August 2014) User Manual
Page 31: Hardware preparation and installation
Hardware Preparation and Installation
MVME2500-ECC Installation and Use (6806800N30F)
31
2.3.1
Environmental Requirements
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
Table 2-1 Environmental Requirements
Characteristics
Commercial Versions
Extended Temperature Versions
Applicable Variants
MVME2500-01080101E
MVME2500-01080101S
MVME2500-02120201E
MVME2500-02120201S
MVME2500-02100202E
MVME2500-02100202S
Cooling Method
Forced Air 27 CFM
1
Forced Air 27 CFM
1
Operating
Temperature
0°C to +55°C
-40°C to +71°C
Storage
-40°C to +85°C
-50°C to +100°C
Vibration Sine
(10min/axis)
2 G, 5 to 2000 Hz
10 G, 15 to 2000 Hz
Vibration Random
(1hr/axis)
0.01g2/Hz, 15 to 2000 Hz
0.04g2/Hz, 15 to 2000 Hz (8
GRMS)
2
Shock
20g/11 mS
30g/11 mS
Humidity
to 95% RH (non-condensing)
to 100% RH (non-condensing)
1. ft3/min minimum