beautypg.com

4 i2c bus device addressing, 5 ethernet phy address, Table 7-3 – Artesyn MVME2500 ECC Installation and Use (August 2014) User Manual

Page 124: I2c bus device addressing, Table 7-4, Phy types and mii management bus address, Programming model

background image

Programming Model

MVME2500-ECC Installation and Use (6806800N30F)

124

7.4

I2C Bus Device Addressing

The following table contains the I2C devices used for the MVME2500-ECC and its assigned
device address.

1. This is a dual address serial EEPROM.

2. The RTM Bus address can be manually changed through the S1 Switch on RTM. The default

switch configuration will set the address to 0x55. Make sure that the address is unique to
the RTM Bus address when setting the switch.

3. The address of the XMC EEPROM is configured through Geographic Address resistor on

board.

7.5

Ethernet PHY Address

The assigned Ethernet PHY on the MII management bus is shown in the following table.

Table 7-3 I2C Bus Device Addressing

I2C Bus Address

Device Function

Size

Notes

0x50

SPD

256 x 8

0x4C

ADT 7461 Temperature Sensor

N/A

0x68

DS 1375 real-time clock

N/A

0x54

VPD

8192 x 8

1

0x52

User configuration

65536 x 8

1

0x53

User configuration

65536 x 8

1

0x55

RTM EEPROM

8192 X 8

1, 2

0x56

XMC EEPROM

N/A

3

Table 7-4 PHY Types and MII Management Bus Address

Ethernet Port

Function / Location

PHY Types

PHY MIIM
Address

TSEC1

Gigabit Ethernet port routed to front panel

BCM54616