4 i2c bus device addressing, 5 ethernet phy address, Table 7-3 – Artesyn MVME2500 ECC Installation and Use (August 2014) User Manual
Page 124: I2c bus device addressing, Table 7-4, Phy types and mii management bus address, Programming model
![background image](https://www.manualsdir.com/files/772506/content/doc124.png)
Programming Model
MVME2500-ECC Installation and Use (6806800N30F)
124
7.4
I2C Bus Device Addressing
The following table contains the I2C devices used for the MVME2500-ECC and its assigned
device address.
1. This is a dual address serial EEPROM.
2. The RTM Bus address can be manually changed through the S1 Switch on RTM. The default
switch configuration will set the address to 0x55. Make sure that the address is unique to
the RTM Bus address when setting the switch.
3. The address of the XMC EEPROM is configured through Geographic Address resistor on
board.
7.5
Ethernet PHY Address
The assigned Ethernet PHY on the MII management bus is shown in the following table.
Table 7-3 I2C Bus Device Addressing
I2C Bus Address
Device Function
Size
Notes
0x50
SPD
256 x 8
0x4C
ADT 7461 Temperature Sensor
N/A
0x68
DS 1375 real-time clock
N/A
0x54
VPD
8192 x 8
1
0x52
User configuration
65536 x 8
1
0x53
User configuration
65536 x 8
1
0x55
RTM EEPROM
8192 X 8
1, 2
0x56
XMC EEPROM
N/A
3
Table 7-4 PHY Types and MII Management Bus Address
Ethernet Port
Function / Location
PHY Types
PHY MIIM
Address
TSEC1
Gigabit Ethernet port routed to front panel
BCM54616
1