ENTRY

DESCRIPTION

(2E+05). The display has insufficient characters to display the
entire mantissa so entering values above 2E+05 from the
keyboard is not recommended.

TRIG SOURCE

Indicates the trigger source for transient system. Available
trigger sources are:

IMM

Immediate mode. The transient is started from
the front panel using the ENTER key.

BUS

Bus mode. The transient system is started by a
bus command or a group execute trigger (GET).

EXT

External mode. The transient system is started
by a user-provided external TTL trigger signal on
TRIGGER IN.

TRAN STEP

Indicates the transient system execution mode. Available
modes are:

AUTO

When triggered, the transient system will
automatically execute each list point sequentially
without waiting for a trigger between list points.
This execution is paced by the dwell time set for
each data point.

ONCE

When triggered, the transient system will
execute the first list point and wait for a new
trigger once the dwell time expires. This allows
triggered execution of each step in the transient
list.

List parameters:

VOLT

Step #

Voltage set point

VSLEW

Step #

Voltage slew rate in V/s

FREQ

Step #

Frequency set point

FSLEW

Step #

Frequency slew rate in Hz/s

DWELL

Step #

Dwell time in seconds.
Range is 0.001 to 900000

TTLT

Step #

ON:

Generates an output trigger pulse at this

list step.
OFF:

No output trigger.

The output trigger is available on the TRIG OUT
on the rear panel. (Aux I/O DB9 connector).

FUNC

Step #

Waveform selection. Available choices are