Number

Message String

Cause

Remedy

45

"Current self test error,
output 3

No. 3/C amplifier in Aux.
Source has no output
during Self-test. Three
phase models only.

Contact CI service department at

[email protected]

216

" RS-232 receiver
framing error"

Communication failure.

Check USB/LAN port settings and cable.

217

" RS-232 receiver parity
error"

Communication failure.

Check USB/LAN port settings and cable.

218

" RS-232 receiver
overrun error"

Communication failure.

Check USB/LAN port settings and cable.

402

"CAL password is
incorrect"

Calibration password
does not equal high
voltage range value.

Re-enter correct password.

403

"CAL not enabled"

No password entered for
calibration

Enter correct CAL password.

600

"Systems in mode:list
have different list
lengths"

Transient lists have
unequal lengths

Check list settings and correct to same
no of data points.

601

"Requested voltage and
waveform exceeds peak
voltage capability"

Wave shape selected and
RMS voltage combine to
exceed peak voltage
capability.

Reduce RMS or crest factor of wave
shape.

602

"Requested voltage and
waveform exceeds
transformer volt-second
rating"

The selected wave shape
exceeds output
transformer capability.

The volt-second product of he waveform
(magnitude and time in the + and

– half

of wave form).

603

"Command only applies
to RS-232 interface"

Command not relevant for
GPIB interface.

Do not use command.

604

"Trigger received before
requested number of
pre-trigger readings"

Data acquisition pre-
trigger buffer not filled yet.

Hold off trigger or reduce pre-trigger
delay.

605

"Requested RMS current
too high for voltage
range"

Max RMS current is
function of voltage range
selected.

Reduce programmed RMS current limit
or select low voltage range.

606

"Waveform data not
defined"

No waveform name
specified

Specify waveform name before sending
waveform data.

607

"VOLT,VOLT:SLEW, and
FUNC:SHAPe modes
incompatible"

Conflict between wave
shape and programmed
slew

Reduce slew or change waveform type.

608

"Measurement
overrange"

Measurement data out of
range.

609

"Output buffer overrun"

Too much data in output
buffer.

Check receive mode on application
program. Program is not reading data
sent by AC source.

610

"Command cannot be
given with present
SYST:CONF setting"

Command conflicts with
available hardware or
firmware option settings.

Check configuration for available options
and features.

801

"Output volt fault"

- Output voltage does not
match program value
when ALC is on.
- Over load
- Voltage kick-back
- No output voltage

Load exceeds current limit and unit is in
Constant Voltage (CV) mode of
operation.
- Reduce load or increase CL setting.
Output voltage is driven above
programmed voltage by external
influence (Load, voltage kickback, etc.)