AMETEK Compact i/iX Series User Manual
Page 106
User Manual
Compact i/iX Series
AMETEK Programmable Power
California Instruments
106
DIP SWITCH S2
– 4 Positions
For 6005-701-1 control board (Assy rev G or lower) DIP switch S2 configures the source of the error
amplifier drive signal for multiple module master/auxiliary systems. New versions of the 6005-701-1
control board (Assy rev H or higher) have a 2 position S2 dip switch instead. See below.
DIP SWITCH
POSITION
NAME
FUNCTION
1
EL
ON to connect External Left error amplifier signal to external cable.
This switch must be ON for all multiple module single-phase
systems. This switch must be OFF for any single module system.
2
EC
ON to connect External Common amplifier signal to external cable.
This switch must be ON for all multiple module single-phase
systems. This switch must be OFF for any single module system.
3
IL
ON to connect error amplifier signal of module’s LEFT amplifier the
master error amplifier signal. This switch must be ON for any single
module system, or if the module is a master in a multiple module
system. This switch must be OFF if the LEFT amplifier of the module
is auxiliary to a different master.
4
IC
ON to connect common of module’s LEFT amplifier as the master
common signal. This switch must be ON for any single module
system. This switch must be OFF if the LEFT amplifier of the module
is auxiliary to a different master.
DIP SWITCH S2
– 2 Positions
For 6005-701-1 control board (Assy rev H or higher) DIP switch S2 configures the source of the error
amplifier drive signal for multiple module master/auxiliary systems. Older versions of the 6005-701-1
control board (Assy rev G or lower) have a 4 position S2 dip switch instead. See above.
DIP SWITCH
POSITION
NAME
FUNCTION
1
IL
ON to connect error amplifier signal of module’s LEFT amplifier the
master error amplifier signal. This switch must be ON for any single
module system, or if the module is a master in a multiple module
system. This switch must be OFF if the LEFT amplifier of the module
is auxiliary to a different master.
2
IC
ON to connect common of module’s LEFT amplifier as the master
common signal. This switch must be ON for any single module
system. This switch must be OFF if the LEFT amplifier of the module
is auxiliary to a different master.
DIP SWITCH S3
DIP switch S3 selects whether the RIGHT amplifier of the module is independent or auxiliary to a
different master.
DIP SWITCH
POSITION
NAME
FUNCTION
1
MRR
ON = MasterRight. This switch must be ON for RIGHT amplifier to be
it’s own master. This switch must be OFF if RIGHT amplifier is
auxiliary to another master.
2
SLR
ON = SlaveRight. This switch must be ON for RIGHT amplifier to be
an auxiliary (slave). This switch must be OFF if RIGHT amplifier is it’s
own master.