beautypg.com

AMETEK Compact i/iX Series User Manual

Page 104

background image

User Manual

Compact i/iX Series

AMETEK Programmable Power

California Instruments

104

7.6 Amplifier Module Data

This section lists the various connectors and interface pin outs to the 6005-400-1 amplifier module.

7.6.1 CONTROL BOARD

7.6.1.1 J1 - LV POWER

PINS

NAME

DESCRIPTION

1,2,3

+24V_FAN

+12.0 Vdc to +24.0 Vdc @ 200 mAdc for module fan. Voltage is
externally controlled according to output current.

4,5,6

FAN_COM

Return for +24V_FAN

7,8

+15G

+15 Vdc +/- 0.5Vdc @ 450 mAdc for gate drive

9,10

G_COM

Return for +15G

11,12

+15LV

+15 Vdc +/- 0.5Vdc @ 150 mAdc for control circuits

13,14

LV_COM

Return for +15LV and

–15LV

15,16

-15_LV

-15Vdc +/-0.5Vdc @ 100 mAdc for control circuits

7.6.1.2 J5 - FAN

PINS

NAME

DESCRIPTION

1

FAN_COM

Return for fan

2

+24V_FAN

DC voltage for fan

7.6.1.3 J6 - E/A IN/OUT

PINS

NAME

DESCRIPTION

1

E/A COM

Return for E/A IN/OUT

2

E/A IN/OUT

Error amplifier signal from master module to parallel auxiliary
modules

7.6.1.4 J2 - CONTROL SIGNALS

PINS

NAME

DESCRIPTION

1

A_COM

Analog common

2

A_SIG_HI

Phase A oscillator signal, 16 Hz to 1 kHz, 0

– 5.3 Vac

3

B_SIG_HI

Phase B oscillator signal, values same as A_SIG_HI

4

C_SIG_HI

Phase C oscillator signal, values same as A_SIG_HI

5

SCOM

Signal common for A/B/C_SIG_HI

6

DCOM

Digital logic common

7

LO_RNG

Low Range control signal, input to module, TTL LO = Low Voltage
Range, TTL HI = High Voltage Range

8

/AMP_FLT

Amplifier fault indicator signal, output from module, open collector,
LO = blown fuse fault detected, HI = normal

9

SUM

Not used

10

/OVT

Overtemperature fault indicator signal, output from module, open
collector, LO = Over temp fault detected, HI = normal