2.11 WHM Option - Supplemental Specification

The following measurment accuracy specifications apply to the Watt Hour meter mode of operation:

Parameter

Specification

Watt-Hour

Range: 0

– 999,999.9 WH

Resolution: 0.1 WH

Accuracy:

0.5% R +10 WH

Etime

Range:

0:00:00 to 9999:59:59

Resolution:

1 sec

Accuracy:

0.025 %

2.12 Supplemental Specifications

Supplemental specifications are provided for reference only and are not guaranteed. Data is based on
typical performance of a Compact i/iX series power source but not verified on each unit produced as
part of AMETEK Programmable Power acceptance test.

Results on individual units may vary from the data provided here.

2.12.1 Output

Output Parameter

Specification

Frequency response:

See

Figure 2-9

Max. Voltage slew:

4V/us, measured step response into resistive load, 10% to 90 % full-

scale voltage.

Load Transient response

No load to full load:

Voltage recovers to within 2% in less than 2 ms

Full load to no load:

Voltage recovers to within 2% in less than 2 ms

Load Regulation response in
ALC mode

< 300 ms

Load Regulation:
(ALC mode OFF)

< 3 % FS

1

1

FS (Full Scale) refers to highest available range, e.g. 300Vac in AC mode, 400Vdc in DC mode.