beautypg.com

AMETEK Compact i/iX Series User Manual

Page 15

background image

User Manual

Compact i/iX Series

AMETEK Programmable Power

California Instruments

15

Output Parameter

Specification

DC Mode

– Series I

High Voltage range

1.25 Adc @ 400 V
1.67 Adc @ 300 V

2.5 Adc @ 400 V

3.25 Adc @ 300 V

Low Voltage range

1.25 Adc @ 200 V
1.67 Adc @ 150 V

1.25 Adc @ 200 V
1.63 Adc @ 150 V

DC Mode

– Series II

High Voltage range

1.25 Adc @ 400 V
1.67 Adc @ 300 V

2.5 Adc @ 400 V

3.25 Adc @ 300 V

Low Voltage range

2.5 Adc @ 200 V

3.25 Adc @ 150 V

5.0 Adc @ 200 V
6.5 Adc @ 150 V

Model

751i / iX

1501i / iX

AC+DC Mode

High Voltage range

1.25 Arms @ 300 V
1.63 Arms @ 230 V

2.5 Arms @ 300 V

3.25 Arms @ 230 V

Low Voltage range

2.5 Arms @ 150 V

3.25 Arms @ 115 V

5.0 Arms @ 150 V
6.5 Arms @ 115 V

Current Limit mode

Programming resolution

Programmable, CC or CV mode

0.01A

Note: Constant power mode allows higher current at reduced voltage. Maximum current available at 77% of

voltage range. See Figure 2-1 through Figure 2-8 for voltage versus current profiles by model and
voltage range.

Maximum AC Peak Current

AC mode, High Vrange

AC mode, Low Vrange

10 Apk
20 Apk

20 Apk
40 Apk

Crest Factor AC Current

Maximum CF at full scale
voltage rms current

4:1

Power

Model

751i / iX

1501i / iX

AC Mode

750 VA

1500 VA

DC Mode (Series I)

High Voltage range

500 W

1000 W

Low Voltage range

250 W

250 W

DC Mode (Series II)

500 W

1000 W

AC+DC Mode

375 VA

750 VA

Frequency

Range:

16 Hz - 1000 Hz

Resolution

1

:

0.01 Hz

[< 81.91 Hz]

0.1 Hz

[> 82.0 to 819.1 Hz]

1 Hz

[> 819 Hz]

1

Programming resolution reduced if

–LKM/-LKS option is installed. See paragraph 2.9.