2.1.2 Output

Output Parameter

Specification

Modes

i models:

AC, DC

iX models:

AC, DC, AC+DC

Voltage

Ranges (L-N):

AC, AC+DC Mode

Low Vrange:

0 - 150 Vrms

High Vrange:

0 - 300 Vrms

DC Mode

Low Vrange:

0 - 200 Vdc

High Vrange:

0 - 400 Vdc

Programming Resolution:

0.1 V

Accuracy:
(ALC mode ON)

0.1% FS

1

(from 5V to FS

1

)

Distortion THD

2

:

< 1 %

16 - 1000 Hz

(harmonics and noise to 300 kHz)

Load Regulation:
(ALC mode ON)

0.1 % FS

1

Voltage Sense modes:

Internal

External

External Sense

Up to 3 % of set voltage can be dropped across each load lead.

Line Regulation:

0.02% for 10% input line change

DC Offset Voltage:

(In AC mode)

< 20.0 mV

Output Noise:

(20 kHz to 1 MHz, full R load)

< 100 mV

RMS

150V / 200V Range

< 200 mV

RMS

300V / 400V Range

Output Coupling

Direct coupled

Output Impedance (Z) (@
max current)

Z = Vrange * 0.001 / I_load

Current

Model

751i / iX

1501i / iX

AC Mode

High Voltage range

2.5 Arms @ 300 V

3.25 Arms @ 230 V

5.0 Arms @ 300 V
6.5 Arms @ 230 V

Low Voltage range

5.0 Arms @ 150 V
6.5 Arms @ 115 V

10.0 Arms @ 150 V
13.0 Arms @ 115 V

Model

751i / iX

1501i / iX

1

FS (Full Scale) refers to highest available range, e.g. 300Vac in AC mode, 400Vdc in DC mode.

2