AMETEK Compact i/iX Series User Manual
Page 155
User Manual
Compact i/iX Series
AMETEK Programmable Power
California Instruments
155
Number
Message String
Cause
Remedy
826
“Peak current prot trip”
Peak current limit
exceeded.
Peak current exceeded. Could be
caused by switching EUT on or off.
827
“Frequency error”
Frequency error during
self-test.
Correct frequency was not measured
during self-test. May be result of 801
error.
828
“Phase error”
Self test error phase
angle
Correct phase angle was not measured
during self-test. May be result of 801
error.
829
“Dc component exceed
limit”
Too much DC content in
loaded ARB waveform.
Check waveform programming.
830
"Lan connection missing” LAN Cable is not
connected
Make sure the LAN cable is connected
to a network.
831
"Duplicate IP,Set to
DHCP”
It detect a duplicate IP on
the network.
Change IP or Cycle power to connect to
DHCP or Auto IP.
832
"Duplicate IP,REM set
reject”
The IP set from remote
interface is rejected.
The IP is rejected use different IP. It is a
duplicate IP or out of reach IP.
833
“Duplicate IP,LOC set
rejec”
The IP set from front
panel keypad is rejected
The IP is rejected use different IP. It is a
duplicate IP or out of reach IP.
834
"Out of reach IP"
The IP set is out of reach
Use an IP within the sub net.
Table 16-1: Error Messages