beautypg.com

Service – AMETEK Compact i/iX Series User Manual

Page 101

background image

User Manual

Compact i/iX Series

AMETEK Programmable Power

California Instruments

101

7. Service

7.1 Cleaning

The exterior of the power source may be cleaned with a cloth dampened with a mild detergent and
wrung out. Disconnect mains power to the source before cleaning. Do not spray water or other
cleaning agents directly on the power source.

7.2 General

This section describes the suggested maintenance and troubleshooting procedures. The
troubleshooting procedure is divided into two sections. The first section deals with basic operation and
connection of the equipment. The second section requires opening the unit and using LED indicators
and a simple multimeter to troubleshoot the unit down to the module level. Only a qualified electronic
technician should attempt this level of troubleshooting.

7.3 Basic operation

PARAGRAPH

PROBLEM

7.3.1

Excessive Output Voltage

7.3.2

Poor Output Voltage Regulation

7.3.3

Overcurrent Light On

7.3.4

Distorted Output

7.3.5

No Output and no lights on front panel

7.3.6

No output, but front panel controller is active.

7.3.1 Excessive Output Voltage

CAUSE

SOLUTION

External sense not connected(If used)

Connect external sense wires on the rear
panel from TB1-1 to TB1-2 and from TB1-
3 to TB1-4

7.3.2 Poor Output Voltage Regulation

CAUSE

SOLUTION

Unit is overloaded

Remove overload

Unit is programmed to wrong voltage
range.

Select correct voltage range.

Input line has fallen below spec. limit.

Check input supply voltage.