AMETEK Compact i/iX Series User Manual
Page 103

User Manual
Compact i/iX Series
AMETEK Programmable Power
California Instruments
103
7.4 Self test
A self test can be performed over the bus by sending the *TST? query command. The self-test will run
until the first error is encountered and terminate. The response to the query will either be the first error
encountered or 0 if no error was found. (Self-test passed).
To execute a self-test, the IEEE-488, LAN or USB interface must be used. The iXCGui command self-
test window can be used to send the *TST? Command. See the section 9 for possible self test error
codes and messages.
7.5 Advanced Troubleshooting.
WARNING:
Do not connect 230V AC input to a unit set for 115V input, the result
could be a severely damaged unit.
CAUTION:
VOLTAGES UP TO 230 VAC AND 500 VDC ARE PRESENT IN CERTAIN
SECTIONS OF THIS POWER SOURCE.
WARNING:
THIS EQUIPMENT GENERATES POTENTIALLY LETHAL VOLTAGES.
DEATH ON CONTACT MAY RESULT IF PERSONNEL FAIL TO OBSERVE SAFETY
PRECAUTIONS. DO NOT TOUCH ELECTRONIC CIRCUITS WHEN POWER IS APPLIED
Switch Off Units
Switch off each unit at the circuit breaker on the front panel as well as removing the input power from
the unit.
WARNING:
Wait 10 minutes for all internal capacitors to discharge.
Removing Cover
Remove the screws securing the top cover and remove it.
Initial Inspection
Make a visual inspection of the unit and ensure all the connectors are properly mated and there are no
loose wires.